Capillary Refill Test
What is the "Capillary Refill Test" used for?
- The capillary refill test provides gross information on the quality and quantity of blood flow to the extremities.
How to perform the "Capillary Refill Test"?
- Squeeze the fingernail so that the nail bed turns white or a lighter shade and hold for 5 seconds.
- Release the pressure and note the speed of the refill as indicated by the baseline color returning to the nail bed.
- Repeat using the other fingers or toes and then perform on the opposite extremity.
What is the positive result?
- Normal capillary refill time is usually 3 seconds or less.
- A positive test is when markedly slow or absent return of the nail’s natural color for more than 3 seconds.
A delayed capillary refill time is a sign of:
- Unilateral positive test: Occlusion of an artery or arteriole supplying the finger.
- Bilateral positive test: Possible systemic cardiovascular compromise or disease.
Test Accuracy
- No standardized execution or evidence demonstrates the area of the digit giving the most accurate capillary refill time (CRT).